Mechanical Installation Load Cell Troubleshooting 101
The performance of a load cell force measurement system depends on the reliability of the physical installation, the correct interconnection of the components, the proper performance of the basic components that make up the system, and the calibration of the system.
Interface provides installation instructions available for its products. Read the installation instructions and have them available for installation and troubleshooting. Load cells that are not installed in accordance with the manufacturer's recommendations may not comply Construction specifications.
Always begin troubleshooting with a physical inspection of the load or weighing sensor. Resistance results from numerous factors that lead to an inaccurate reading and possible overload. If dents, bends, cracks or deformation are visible, the device probably needs to be replaced repaired or replaced become. If none of these conditions are apparent, the next step is to troubleshoot the mechanical installation.
Below is a quick checklist for troubleshooting mechanical installations:
- Check mounting surfaces for cleanliness, flatness and alignment.
- Check the tightening torque of all fastening parts
- Check the alignment of the load cell
- Verify the use of the correct hardware required to connect the load to the load cell.
- Check cables or output devices
The orientation of a load cell is defined by the “dead” end connected to a mechanical reference or power source and the “active” end connected to the load being measured by the cell. The dead end is the end that is mechanically closest to the cable exit or connector. A fundamental requirement is that there is one, and only one, load path. This load path must run through the load axis of the load cell. This may sound elementary, but it is an often overlooked problem.
When troubleshooting during mechanical installation, check all of them Hardware and accessories, including all connectors, cables, thread sizes, lock nuts, swivels, brackets and bolts. It is always important to thoroughly check the cables used in a system as well. Inspect the cables to ensure there are no bruises, cuts, or exposed wires. This is a common cause of mechanical installation errors.
For quick reference, here is a discussion of what a healthy load cell should look like and what visual signs may indicate a malfunctioning load cell.