Transfer standard and reference standard series 1800
Characteristics
- Platinum Series - Transfer Standard
- Class 00 according to ISO-376
- Multi-axial/measuring bridges
- with calibration adapter (manufactured)
The specifications of the interface Platinum Series 1800 correspond to at least class 00 of ISO376*** and are used in numerous national metrology institutes or calibration laboratories. In order to actually meet the highest demands for precision force measurements, the measuring spring is manufactured directly from one part with the calibration adapter and 16 selected strain gauges from our own production are used.
*** Standard: Calibration of force measuring devices for testing testing machines with uniaxial loading.
- Low Profile® design
- DAkkS-A2LA-ILAC
- Options.
- Accessories
Interface force transducers and/or torque transducers are supplied with a calibration certificate as standard. The Interface Inc. calibration laboratory is A17025LA accredited (in accordance with ISO/IEC 2).. Both the A2LA (American Associations for Laboratory Accreditation) and, among others, the DAkkS (German Accreditation Body) have signed the multilateral agreement MRA (Mutual Recognition Arrangement) for the mutual recognition of accreditations at the ILAC (International Laboratory Accreditation Cooperation).
> This means that the calibrations must be mutually recognized
[Interface force transducers and or torque transducers are supplied with a calibration certificate as standard. The Interface Inc. calibration laboratory is A2LA accredited (in accordance with ISO / IEC 17025). Both, the A2LA (American Associations for Laboratory Accreditation) and the DAkkS (German Accreditation Body) have signed the multilateral agreement MRA (Mutual Recognition Arrangement) for the mutual recognition of accreditations at the ILAC (International Laboratory Accreditation Cooperation).]
> This means that the calibrations are mutually recognized
• Special thread/adapter
• Bending moment measuring bridges
• other Fz measuring bridges
• special connection plugs/assignment
• TEDS – electronic data sheet in the sensor
• DAkkS calibration
• special mV/V output signals
• Shut resistors,
and much more…. Please contact us
Signal conditioning:
• Precision measuring amplifier model 9840
• Gold standard measuring amplifier
• Software e.g. for ISO-376 & ISO 7500-1
• Handheld devices with TEDS
• TEDS – Transducer Electronic Datasheet
• mV/V simulators CX series
• Shunt resistors
• Mating connector & connection cable
Mechanical adapters & installation aids:
• Calibration adapter according to ISO-376
• Pressure load adapter
• Locknuts
• Thread adapter
• Articulated eyes & eyelets
• Mounting plates