Calibration force transducer Gold Standard 1600 + 1601
Characteristics
- Reference or transfer standard
- Measuring ranges from 2kN to 1MN
- Class 00 or 05 according to ISO-376
- Optional: bending moment measuring bridges
The Gold Standard Series 1600 (tension and compression / 1601 – compression only) was developed specifically for calibration applications. Based on the Shear Web or shear stress measurement principle, the 1600 and 1601 series features installed calibration adapters particularly small linearity errors, hysteresis errors and creep errors and is therefore suitable, for example, for calibration tasks or testing applications in industry and research with particularly high requirements. The gold standard series allowed corresponds at least to that Class 05 according to ISO-376 (optional Class 00) and is often used for machine calibrations according to ISO-7500-1 or as a transfer standard for calibration machines. A special mechanical balancing process minimizes crosstalk of bending moments and/or off-center loads.
As an option, we also offer bending moment measuring bridges to monitor parasitic loads.
- ISO-17025 accreditation
- Low Profile® design
- Options.
Interface force transducers and/or torque transducers are supplied with a calibration certificate as standard. The Interface Inc. calibration laboratory is A17025LA accredited (in accordance with ISO/IEC 2).. Both the A2LA (American Associations for Laboratory Accreditation) and, among others, the DAkkS (German Accreditation Body) have signed the multilateral agreement MRA (Mutual Recognition Arrangement) for the mutual recognition of accreditations at the ILAC (International Laboratory Accreditation Cooperation).
> This means that the calibrations must be mutually recognized
[Interface force transducers and or torque transducers are supplied with a calibration certificate as standard. The Interface Inc. calibration laboratory is A2LA accredited (in accordance with ISO / IEC 17025). Both, the A2LA (American Associations for Laboratory Accreditation) and the DAkkS (German Accreditation Body) have signed the multilateral agreement MRA (Mutual Recognition Arrangement) for the mutual recognition of accreditations at the ILAC (International Laboratory Accreditation Cooperation).]
> This means that the calibrations are mutually recognized
• Special thread/adapter
• countersunk threaded holes (standard for print only)
• Bending moment measuring bridges
• increased overload protection
• special connection plugs/assignment
• Connection cable (model / length)
• TEDS – electronic data sheet in the sensor
• DAkkS calibration
• Custom nameplates/painting
• special mV/V output signals
• Shunt resistors,
our (top 4 selection) for suitable options: