Calibration & Service
If you wish to send in a sensor or measuring instrument for repair, please proceed as follows: fill out the form below and describe your request as comprehensively and precisely as possible. You will immediately receive an RMA number , which you can refer to. Our laboratories are ISO 17025 accredited and offer extensive capabilities, including manufacturer-independent DAkkS (or A2LA) calibrations and repairs, across borders with short turnaround times. Examples include: ISO 376 / DKD-R3-3 / ASTM E74 / factory calibrations / system calibrations with setup / conformity assessment by arrangement.
Please deliver exclusively to:
interfaceforce® eK
c/o SETFLEX – Mr. Mols
Oppelner Str. 23
D-41199 Mönchengladbach
+49 2166 9977820
Service calibration delivery conditions:
All information will be treated confidentially unless we are legally obligated to do otherwise. Calibrations are performed using static forces (tensile and/or compressive force) or static moments (left and/or right moment). The determined calibration values are valid at the time of calibration. If it becomes apparent during calibration that the sensor and/or amplifier is not calibratable, no calibration certificate will be issued, and the costs for the measurements performed will be invoiced (pro rata). All devices must be clearly labeled and delivered with appropriate documentation and in perfect working order. The customer bears the costs for transport, customs clearance, and packaging (unless the delivery packaging also serves as return packaging) of the item being calibrated. interfaceforce guarantees the proper calibration of the devices but assumes no liability arising from the use and operation of the calibrated devices. interfaceforce is not liable for damage to the item being calibrated resulting from mishandling due to incorrect information, labeling, latent defects, or defects not reported by the customer. The laws of the Federal Republic of Germany shall apply exclusively. Due to the EU General Data Protection Regulation (GDPR), we ask that you completely remove any personal and sensitive information from your laptop or PC. To prevent the loss of your data or measurements during transport or repair, we urge you to create a backup beforehand and store it in a safe place.
Both the A2LA (American Association for Laboratory Accreditation) and, among others, the DAkkS (German Accreditation Body) have signed the multilateral Mutual Recognition Arrangement (MRA) for the mutual recognition of accreditations at the ILAC (International Laboratory Accreditation Cooperation). This means that calibrations must be mutually recognized.
The A2LA / ISO-17025 accredited calibration laboratory of Interface Inc. offers comprehensive service and inexpensive calibrations; we are happy to offer you a door-to-door service.
- Repairs and calibrations of our force transducers, torque transducers and measuring amplifiers
- also for third-party manufacturers
- Forces up to 5MN tension and pressure and
- Torques up to >10kN*m as well
- tensions and
- tensions
In addition to the comprehensive range of services offered at our headquarters in Scottsdale, we now also offer re-calibrations and system calibrations with short turnaround times here in Germany as an extended service offering of interfaceforce eK, in cooperation with local calibration laboratories .
At the interfaceforce laboratory near Munich, we currently have three calibration facilities with force measurement ranges available, allowing us to calibrate force measuring devices up to class 0,5 according to ISO 376 or DKD-R 3-3 for tensile and compressive forces. A variety of adapters enable us to measure not only standard force transducers and load cells, but also dynamometers and spring scales.
- The force calibration system UCM, from Morehouse, with a measuring range of 2 kN to 250 kN
- The force calibration system PCM, from Morehouse, with a measuring range of 0,5 N to 10 kN (including Gold Standard and Platinum Standard reference force transducers from interface)
- A self-made dead load calibration device with a measuring range of 10 N to 500 N
All standards used are traced back to DAkkS, NIST or PTB. In conjunction with our calibration software, we can now carry out local calibrations according to ISO 376 – DKD-R 3-3 – VDI/VDE 2624 – free calibration processes. Further guidelines such as ASTM 74 follow. In addition to the measurement amplifiers from interface, the software also supports Morehouse and HBM. Other systems can be implemented at an additional cost. In the range from 20 N to 250 kN, calibration is carried out using transfer standards. A loading device with masses is also available for the range from 0,5 N to 500 N. DAkkS accreditation will be applied for shortly. We also offer these solutions for purchase for customers who want to set up their own laboratory. Existing measurement technology can usually continue to be used.